← Back to the Blog

Fire Extinguisher Rules for Boats on Lake Havasu

A boat must carry a Coast Guard approved, marine-type, hand portable B-class fire extinguisher where a fire hazard could be expected from the engines or fuel system, and how many depends on the boat’s length (Coast Guard’s boater guide to federal requirements). Most Havasu boats need at least one 5-B extinguisher. Check the rules that apply to your boat with the Coast Guard and AZGFD.

When you need one

Federal rule 33 CFR 175.320 requires extinguishers when any of these exist, as the Coast Guard guide lists them (Coast Guard’s boater guide to federal requirements):

  • Closed compartments under seats where portable fuel tanks may be stored.
  • Double bottoms not sealed to the hull or not completely filled with flotation material.
  • Closed living spaces.
  • Closed stowage compartments holding combustible or flammable materials.
  • Permanently installed fuel tanks.

The regulation also says a vessel less than 26 feet propelled by an outboard motor is not required to carry extinguishers if the construction of the vessel will not permit the entrapment of explosive or flammable gases or vapors (33 CFR 175.320). The AZGFD handbook adds that federal law requires an extinguisher on any vessel, PWC included, with an inboard engine or any of the conditions above, and Arizona’s checklist shows a 5-B for all boat types (Arizona Game and Fish Department boater handbook). If you are unsure, carry one. It costs far less than the fire.

How many and what size

Boat length No fixed system in engine space With fixed system
Under 16 ft 1 (5-B) 0
16 ft to under 26 ft 1 (5-B) 0
26 ft to under 40 ft 2 (5-B) 1
40 ft up to 65 ft 3 (5-B) 2

This is the Coast Guard’s minimum-number chart for boats with model years 2018 and newer, and the same chart applies to older boats with different allowed ratings (Coast Guard’s boater guide to federal requirements). One 20-B can be substituted for two 5-B. A “fixed system” means a Coast Guard approved fixed extinguishing system protecting the engine compartment.

Which type

  • Class B extinguishes flaming liquids such as gasoline, oil and grease. Required boat extinguishers are Class B, marine type and hand portable, generally 5-B, 10-B or 20-B, with a mounting bracket (Coast Guard’s boater guide to federal requirements).
  • A multipurpose “A:B:C” unit is fine if it is the right size Class B and carries the “Marine Type USCG Approved” label.
  • For model year 2018 and newer boats, the Coast Guard chart counts date-stamped extinguishers rated 5-B or 20-B as the minimum; a compliant extinguisher with a higher rating also counts. Boats from model years 1953 to 2017 may carry 5-B or 20-B, or B-I or B-II rated units in good, serviceable condition (Arizona Game and Fish Department boater handbook).

Where to mount it

It must be readily accessible. The Coast Guard recommends mounting it where it can be reached easily, such as at or near the steering station, the galley or the engine room, but away from locations where a fire is likely to start (Coast Guard’s boater guide to federal requirements). A fire in the engine compartment should not cut you off from the extinguisher.

Check it every trip

The Coast Guard says to inspect extinguishers each time you get underway (Coast Guard’s boater guide to federal requirements):

  1. Seals and tamper indicators are not broken or missing.
  2. The gauge or indicator reads in the operable range.
  3. There is no obvious damage, rust, corrosion, leakage or clogged nozzle.
  4. It is not expired. For non-rechargeable units, that is 12 years from the date stamped on the bottom.
  5. If the label states a minimum weight, weigh it annually.

A partly emptied or damaged extinguisher must be replaced, or refilled by a qualified servicing company if refillable. The handbook also says a non-rechargeable extinguisher older than 12 years should be removed from service (Arizona Game and Fish Department boater handbook).

If there is a fire

This is general practice. Stop the boat, turn off the engine and fuel, get everyone into life jackets and away from the fire, and aim the extinguisher at the base of the flames. Squeeze and sweep from side to side. Call 911 if you have service. If the fire grows, abandon the boat upwind and signal for help (see How to Signal for Help).

Fueling is when it happens

The Coast Guard says most fires and explosions happen during or shortly after fueling. Refuel portable tanks ashore, close hatches, turn off engines and electrics, and after fueling run the blower for at least four minutes and sniff for fumes before starting (Coast Guard’s boater guide to federal requirements).

Owning the right unit

When you look at a boat, find the extinguisher, read its date and ask where else gear is stowed. We do a full inspection before the paperwork is final and show you the reconditioning and maintenance we performed. See our boats.

Related guides

Read Required Safety Equipment Checklist, Fuel System Inspection and How to Fill Boat Gas Properly.

Next step

Call (928) 453-8833, text (928) 732-2281 or visit 1680 Industrial Blvd, Monday to Saturday 8 to 5 and Sunday 9 to 2. Have a boat to sell? We consign it with no fees and send a check within 10 business days after it sells. See consign with us.

Common questions

How many fire extinguishers do I need on my boat?

Under 26 feet, one 5-B if the Coast Guard conditions apply. 26 feet to under 40 feet, two 5-B (one 20-B can replace two 5-B). 40 up to 65 feet, three. A fixed engine-space system reduces the number.

Does an outboard boat need an extinguisher?

A boat under 26 feet with an outboard is exempt only if its construction will not entrap flammable vapors (33 CFR 175.320). Arizona’s checklist lists a 5-B for all boat types, and an extinguisher is the top violation on its list, so carry one.

How long is a fire extinguisher good for?

The Coast Guard says non-rechargeable units are expired 12 years from the date stamped on the bottom.

Can I use a home ABC extinguisher?

It must be marine type and Coast Guard approved, with a Class B rating of 5-B, 10-B or 20-B, or a compliant higher rating. A household unit without the marine type approval label does not meet it.

Where should I mount it?

Where it is readily accessible, near the helm, galley or engine room but away from where a fire is likely to start.

Browse Boats Consign Yours